In-Circuit Testing vs Functional Testing for Electronic Imports
AQL (Acceptable Quality Level) is a statistical sampling method. For most consumer goods, AQL 2.5 for major defects and 4.0 for minor defects is standard. Critical defects always require zero tolerance. The sampling size is determined by ISO 2859 or ANSI/ASQ Z1.4 tables. A batch of 3,000 units requires 125 samples. If more than 7 major defects are found, the entire batch fails and requires 100% inspection. Always specify AQL levels in your purchase contract.
The most common quality problems I've seen across thousands of inspections are: (1) dimensional deviation — products not matching spec measurements, (2) color variation — especially between sample and bulk, (3) surface defects — scratches, dents, rust, (4) packaging damage — inadequate protection, wrong materials, (5) mix of good and defective units in the same carton. A solid QC plan addresses all five.